Chapter 5 Addendum Operating Instructions
S3000 Cold Store
10 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8012029/YY95/2016-02-05
Subject to change without notice
Electrical installation
5.2 Parameter setting and diagnostics connection
For setting the parameters and expanded diagnostics using a PC/laptop, a special service
cable is available for the S3000 Cold Store (RSC232, prepared for serial PC connection;
see section 8.3 “Accessories/spare parts” on page 15). The service cable connection
cables are 5 m long.
In addition to the 9-pin DCSub plug for serial connection to a PC, the service cable has a
separate supply cable with plug for supplying the safety laser scanner with power (does
not include the supply of power to the heater). The supply voltage on the application side is
then fed through to the safety laser scanner.
If the S3000 Cold Store is connected to a bus system using EFI (e.g. via SICK Intelliface
products), configuration or diagnostics can also be performed from outside the cold
environment over the bus system.
However, always check the protective field at the system, the machine or vehicle as per
the test notes in the original operating instructions.