Addendum Operating Instructions Chapter 6
S3000 Cold Store
8012029/YY95/2016-02-05 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 11
Subject to change without notice
Care and maintenance
6 Care and maintenance
Do not open S3000 Cold Store safety laser scanner!
The safety laser scanner is not allowed to be opened! The manufacturer’s warranty will be
rendered void if the device is opened.
6.1 Cleaning the front screen
The S3000 Cold Store safety laser scanner is largely maintenance-free. The front screen
on the safety laser scanner should however be regularly cleaned and also if contaminated.
Do not use aggressive cleaning agents.
Do not use abrasive cleaning agents.
Static charges cause dust particles to be attracted to the front screen. You can diminish
this effect by using the anti-static plastic cleaner (SICK Part No. 5600006) and the SICK
lens cloth (Part No 4003353) (see section 8.3 “Accessories/spare parts” on page 15).
How to clean the front screen:
Use a clean and soft brush to remove dust from the front screen.
Now wipe the front screen with a clean and damp cloth.
If the front screen is scratched or damaged, the device must be replaced. In this case
please contact your SICK subsidiary.
6.2 Replacing desiccant cartridge
The S3000 Cold Store has a desiccant cartridge on the side of the housing for absorbing
residual moisture in the housing (see Fig. 5 on page 13).
Saturation of the desiccant is indicated by the colour changing from blue to red. Then
replace the desiccant. The desiccant cartridge is available as a spare part (see section 8.3
“Accessories/spare parts” on page 15).
It is only allowed to replace the cartridge in a dry room (e.g. in office environment).