Technical specifications
7 Technical specifications
7.1 Data sheet
Minimum Typical Maximum
General data
Enclosure rating IP 65 and IP 67 (EN 60529)
Operating temperature range –30 °C +50 °C
Storage temperature range –30 °C +70 °C
max. 24 h
Housing material
Back plate and connector
housing
Aluminium die cast
Cover Polyurethane (PU), rape yellow
Front screen
Material Polycarbonate
Surface finish Outside with scratch-resistant coating
Dimensions See section 7.2 “Dimensional drawings” on page
13.
Weight, without hardware 9 kg
Functional data
Scan angle 180°
Electrical data
Electrical connection 16-pin plug with screw-type terminals
3 × PG11 cable gland for cable diameter 5-12 mm
Safety laser scanner
Supply voltage (SELV)
2)
. 17.5 V 24 V 28.8 V
Permissible residual ripple ±5 %
Heating
Supply voltage (SELV)
(full heating performance only
at nominal voltage)
21.6 V 24 V 26.4 V
Permissible residual ripple ±5 %
Current required, cyclic (pay
attention to voltage drop on the
supply cable)
4 A
Configuration and diagnostics
interface
RS-232 (proprietary); 38400 Baud
2)
The voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in