Interfaces
Voltage supply
L
ocal inputs and outputs
Male connector, M12, 5-pin, A-coded (common
male connector for voltage supply and outputs)
Male connector, M12, 8 pin, A-coded (common
male connector for voltage supply and inputs
and outputs) or
Male connector, M8, 8-pin, A-coded (common
male connector for voltage supply and outputs)
Flying leads
Length of cable 0.2 m, 3 m or 10 m
Table 21: Electrical data
Electrical data
OSSD pairs 1
Rated impulse withstand voltage U
im
p
1,500 V
Contamination rating 3 (external, according to EN 60947-1)
Power-up delay (after supply voltage applied)
1)
2.5 s
Supply voltage U
V
DC 24 V (19.2 V ... 28.8 V)
Muting time when supply voltage is interrupted 4 ms
Rated insulation voltage Ui DC 32 V
Load capacity 400 nF (at OSSD1 and OSSD2)
2 μF (a
t Out Aux)
External fuse protection (supply voltage) 0.6 A ... 2 A
1 A f
or UL-compliant applications
Current consumption (without load) 50 mA
Protection class III (EN 61140 / IEC 61140)
1)
Once the supply voltage has been switched on, the OSSDs and the application diagnostic output are in
t
he OFF state during the time delay before availability. The specified time applies to one sensor; in a
series connection, 0.1 s must be added per sensor. An additional 0.5 s per taught-in actuator must be
added for uniquely coded and permanently coded sensors.
Table 22: Mechanical data
Mechanical data
Dimensions (W x H x D)
Safety switches
Standard” actuator
“Compact” actuator
“Flat” actuator
“Mini” actuator
40 mm x 18 mm x 26 mm
see
figure 22
see figure 23
see figure 24
see figure 25
Material
Sensor
A
ctuator
Vistal
®
V
istal
®
Weight
Safety switches
Standard” actuator
“Compact” actuator
“Flat” actuator
“Mini” actuator
63 g ... 436 g (depending on variant)
26 g
13 g
13 g
6 g
Table 23: Inputs
Inputs
Rated voltage DC 24 V (19.2 V ... 28.8 V)
11 TECHNICAL DATA
36
O P E R A T I N G I N S T R U C T I O N S | STR1 8018754/12IU/2020-01-30 | SICK
Subject to change without notice

Table of Contents