Alignment of sensor and actuator Assured switch-
on distanc
e S
ao
Assured switch
off distance S
ar
Minimum dis‐
tance with paral‐
lel approach
3 mm
6 mm
1)
15 mm
1)
Only applies in limited temperature range of –10 °C … +70 °C. Devices with serial number 1824*** or
lower only support the limited temperature range. The serial number is displayed on the safety switch
over the data matrix code.
Sensing ranges for “Flat” actuator
T
able 27: Sensing ranges for “Flat” actuator
Alignment of sensor and actuator Assured switch-
on distanc
e S
ao
Assured switch
off distance S
ar
Minimum dis‐
tance with paral‐
lel approach
10 mm
14 mm
1)
28 mm 8 mm
4 mm
6 mm
1)
28 mm 5 mm
3 mm
9 mm
1)
20 mm 4 mm
Not possible
1)
Only applies in limited temperature range of –10 °C … +70 °C. Devices with serial number 1824*** or
lo
wer only support the limited temperature range. The serial number is displayed on the safety switch
over the data matrix code.
TECHNICAL DATA 11