EasyManua.ls Logo

SICK T4000 Multi - T4000-1 KBA Actuator

SICK T4000 Multi
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.2.2 Technical data
Table 8: Technical data of sensors T4000-DNA....
Parameter
Minimum Typical Maximum
Housing material Fortron, fiberglass-reinforced thermoplastic, encapsu‐
la
ted
Dimensions 42 × 25 × 12 mm³
Weight (incl. 10 m cable) 0.3 kg
Ambient temperature –25 °C +70 °C
Enclosure rating IP67/IP69k
Response range
Assured switch-off distance S
ar
S
witch-on distance
Assured switchon distance S
ao
Switching hysteresis
With side approach direction
10 mm
0.5 mm
15 mm
2 mm
3 mm
32 mm
T4000DNA..P sensor connection Permanently encapsulated connecting cable with fer‐
r
ules
Cable length for sensor T4000-
DN
A..P
15 m
T4000-DNAC sensor connection Plug connector M8, 3-pin, with latching and screw con‐
nection
Cable length T4000-DNAC 25 m
11.3 T4000-1KBA actuator
Table 9: Technical data of actuator T4000-1KBA
Parameter
Minimum Typical Maximum
Housing material Fortron, fiberglass-reinforced thermoplastic, encapsu‐
lated
Dimensions 42 × 25 × 12 mm³
Weight 0.02 kg
Ambient temperature –25 °C +70 °C
Enclosure rating IP67/IP69k
Installation position Sensing face opposite sensor
Dwell time
1)
0.5 s
1)
The dwell time is the time in which the actuator must be located inside or outside the response range.
TECHNICAL DATA 11
8022726/2019-05-07 | SICK O P E R A T I N G I N S T R U C T I O N S | T4000 Multi
39
Subject to change without notice