Important information
DANGER
Insufficient checks or incorrect repair
Hazard due to lack of effectiveness of the protective device
b
In the event of wear or damage, replace the entire safety locking device with
actuator. Never replace individual parts or assemblies.
b
Check the safety locking device following the inspection intervals specified in the
national rules and regulations.
Defining the thorough check
b
When defining the thorough check, please note the following:
°
Define the type and execution of the thorough check.
°
Define the frequency of the thorough check.
°
Notify the machine operators of the thorough check and instruct them
accordingly.
The following thorough checks are often defined in connection with a protective
device:
•
Thorough check during commissioning and modifications
•
Regular thorough check
Minimum requirements for the thorough check
The following checks must be done to ensure permanent and proper function:
•
Proper switching function
•
Manual unlock function (e.g., mechanical unlocking mechanism)
•
Safe mounting of all components
•
No damage, contamination, deposits or wear
•
No loose plug connectors
•
No signs of manipulation of the safety locking device
•
No alignment error between the fixed and moving part of the physical guard that
impairs the protection, e.g., gap through which operating personnel can reach.
•
For variants with unique coding: The actuator used is the taught in actuator.
PROJECT PLANNING 4
8019972/1CS1/2022-07-20 | SICK O P E R A T I N G I N S T R U C T I O N S | TR10 Lock
19
Subject to change without notice