EasyManua.ls Logo

SICK TR10 Lock

SICK TR10 Lock
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Important information
DANGER
Insufficient checks or incorrect repair
Hazard due to lack of effectiveness of the protective device
b
In the event of wear or damage, replace the entire safety locking device with
actuator. Never replace individual parts or assemblies.
b
Check the safety locking device following the inspection intervals specified in the
national rules and regulations.
Defining the thorough check
b
When defining the thorough check, please note the following:
°
Define the type and execution of the thorough check.
°
Define the frequency of the thorough check.
°
Notify the machine operators of the thorough check and instruct them
accordingly.
The following thorough checks are often defined in connection with a protective
device:
Thorough check during commissioning and modifications
Regular thorough check
Minimum requirements for the thorough check
The following checks must be done to ensure permanent and proper function:
Proper switching function
Manual unlock function (e.g., mechanical unlocking mechanism)
Safe mounting of all components
No damage, contamination, deposits or wear
No loose plug connectors
No signs of manipulation of the safety locking device
No alignment error between the fixed and moving part of the physical guard that
impairs the protection, e.g., gap through which operating personnel can reach.
For variants with unique coding: The actuator used is the taught in actuator.
PROJECT PLANNING 4
8019972/1CS1/2022-07-20 | SICK O P E R A T I N G I N S T R U C T I O N S | TR10 Lock
19
Subject to change without notice