6.4 Connecting a cascade
Prerequisites
DANGER
Incorrect connection of the safety locking device
Loss of safety function
b
In the case of insulating material/connection strands, observe the necessary
temperature resistance and mechanical load capability.
b
Only use safe contacts for safety functions.
Prerequisites
Mounting is completed.
Electrical installation is carried out according to the project planning.
Dangerous condition of the machine is and remains off during the electrical instal‐
lation.
Outputs of the device have no effect on the machine during electrical installation.
Setting up a cascade
The cascade can be created using special T-connectors and an end connector (see
"Accessories", page 40).
1
2
1 1 1
2
2 2 2
1
3
4 4 4 4
4
5 5 5 5 6
7
Figure 20: Cascade of multiple safety locking devices
1
Safety locking device TR10 Lock
2
M12 connection cable, 8-pin
3
Terminator plug
4
T-connector
5
M12 connection cable, 5-pin
6
M12 connecting cable, 5-pin
7
Safe evaluation unit
ELECTRICAL INSTALLATION 6
8019972/1CS1/2022-07-20 | SICK O P E R A T I N G I N S T R U C T I O N S | TR10 Lock
25
Subject to change without notice