What to do if SICK TR10 Lock Indoor Furnishing fault indicators are repeated?
- Llacey57Aug 2, 2025
If the fault indicators are repeated, perform a reset by interrupting the voltage supply for at least 3 seconds.
What to do if SICK TR10 Lock Indoor Furnishing fault indicators are repeated?
If the fault indicators are repeated, perform a reset by interrupting the voltage supply for at least 3 seconds.
Why can't I teach in more than 8 actuators on my SICK Indoor Furnishing?
No further teach-in processes are possible because 8 actuators have already been taught in. The device flashes three times.
Why can't I teach in my SICK TR10 Lock Indoor Furnishing safety locking device?
No further teach-in processes are possible because the safety locking device is permanently coded. The device flashes three times.
Brand | SICK |
---|---|
Model | TR10 Lock |
Category | Indoor Furnishing |
Language | English |
Explains the purpose, scope, and conventions used in the operating instructions.
Provides links to the SICK website for further product details and documentation.
Covers product integration, mounting, electrical installation, and repair safety requirements.
Defines proper application and lists unsuitable uses to prevent hazards.
Outlines necessary expertise for planning, installation, operation, and maintenance.
Explains how the safety locking device is set up and its core operational principles.
Details product variants, coding options, and OSSD functionality.
Describes how to manually deactivate the lock and the mechanism involved.
Defines roles and responsibilities for machine manufacturers and operating entities.
Covers safe assembly, preventing tampering, and actuation direction.
Details alignment requirements and minimum mounting distance for safety switches.
Covers mounting brackets, switch/actuator level mounting, and alignment aids.
Addresses mounting for CIP applications and near metal particles.
Details electrical integration, OSSD connections, and control logic.
Covers prerequisites, actuator mounting with torque specs, and pin alignment.
Details mounting bracket installation and safety switch mounting with alignment.
Covers alignment variants, actuator raising checks, and collision prevention.
Conditions for using the equipment according to UL 508 requirements.
Details pin assignments and safety notes for M12 and flying lead connections.
Information on setting up multiple devices in series and the connection interface.
Covers device initialization, teach-in for different actuator types, and permanent coding.
Details mechanical and electrical functional tests required after installation and fault correction.
Explains fault indicators for teach-in, cascading, and general faults shown by diagnostic LEDs.
Details features, safety parameters, interfaces, electrical, and mechanical specifications.
Covers response times, OSSD testing, and dimensional drawings of the device components.
Lists all items included in the product package.
Provides tables for ordering universally and uniquely coded TR10 Lock variants.
Lists available actuator types based on coding and principle.
Details ordering for M12 cables, distributors, mounting brackets, and safety screws.
Information on EU/UK declarations of conformity, FCC, and IC radio approvals.