2. Depending on the alignment and environmental influences, dirt may accumulate
in the actuator. In this case, use a screwdriver to pry the sealing plug out of the
actuator. This will prevent dirt from accumulating in the actuator.
Figure 12: Remove sealing plug if necessary
3. Install mounting bracket to the movable protective device with at least 2 M5
screws. Make sure that at least 1 screw uses a drill hole near the actuator (see
figure 14).
M5
M5
Figure 13: Fasten mounting bracket in place with at least 2 M5 screws
Figure 14: Correct and incorrect screw connection options for the mounting bracket
Mounting the safety switch
b
Mount the safety switch with 3 M5 screws. You can ensure correct alignment of
the safety switch and actuator in two ways.
°
Max. torque: 2Nm
°
Use supplied alignment aid.
Figure 15: Alignment of safety switch and actuator, variant 1
°
Use 4 ... 9mm for distance “H”.
MOUNTING 5
8019972/1CS1/2022-07-20 | SICK O P E R A T I N G I N S T R U C T I O N S | TR10 Lock
21
Subject to change without notice