6 Electrical installation
6.1 Notes on cULus
The following conditions must also be fulfilled in order to use and apply the equipment
in accordance with UL508 requirements:
The voltage supply must conform to Class2 according to UL508.
Connections In 1 and In 2 must conform to Class 2 according to UL508.
The required fuse protection for each device is 1A. In a safe series connection, a
suitable device fuse protection must be calculated.
6.2 Device connection (M12, 8-pin)
Important information
DANGER
Incorrect connection of the safety locking device
Loss of safety function
b
In the case of insulating material/connection strands, observe the necessary
temperature resistance and mechanical load capability.
b
Only use safe contacts for safety functions.
Prerequisites
Mounting is completed.
Electrical installation is carried out according to the project planning.
Dangerous condition of the machine is and remains off during the electrical instal‐
lation.
Outputs of the device have no effect on the machine during electrical installation.
With insulation material or connection slots, pay attention to the temperature
resistance and mechanical load capability. For safety functions, use only safe
contacts.
Figure 19: Device connection (male connector, M12, 8-pin, A-coded)
Device connection (M12, 8-pin)
Table 2: Pin assignment for device connection (male connector, M12, 8-pin, A-coded)
Pin Wire color
1)
Designation Description
1 White Out AUX Application diagnostic output
(not secure)
2 Brown +24VDC Voltage supply 24VDC
3 Green Lock Lock input
4 Yellow In 2 OSSD 2 input
2)
5 Gray Output signal switching device
(OSSD) 1
Output OSSD 1
6 Pink Output signal switching device
(OSSD) 2
Output OSSD 2
ELECTRICAL INSTALLATION 6
8019972/1CS1/2022-07-20 | SICK O P E R A T I N G I N S T R U C T I O N S | TR10 Lock
23