Interfaces
Voltage supply
Local inputs and outputs
Cable with male connector, M12, 8-pin, A-coded (common male
connector for voltage supply and inputs and outputs) or
Flying leads
Length of M12 connecting
cable
0.2m
Length of open wire connect‐
ing cable
3m
10m
Table 13: Electrical data
Electrical data
Supply voltage U
v
24VDC (20.4V ... 26.4V) (SELV)
Protection class II (EN61140/IEC61140)
Locking principle
TR10-SRxxxx
TR10-SLxxxx
“Power to release” principle
“Power to lock” principle
Power consumption in passive
state (lock activated or deacti‐
vated)
2.5W
Usage category DC-13: 24V, 200mA (IEC 60947-5-2)
Max. output current (per out‐
put)
200mA
Peak current (when activating,
deactivating, or switching on)
400mA, 100ms
Rated insulation voltage Ui 70V DC(IEC 60947-1)
Rated impulse withstand volt‐
age U
imp
1,000V (IEC 60947-5-1)
Power-up delay after applying
supply voltage
8s time delay before availability
Thermal current l
th
0.2A
Contamination rating 3 (EN 60947-1)
1)
At 10mA.
Table 14: Mechanical data
Mechanical data
Dimensions (W x H x D)
Safety switch
Actuator with mounting
bracket
45mm x140mm x50mm
40mm x65mm x51.5mm
Material
Housing
Guard locking pin
Cable
Mounting bracket
Acrylonitrile butadiene styrene (ABS)
Stainless steel (304)
PVC
Stainless steel (304)
Weight
Safety locking device
Actuator
Mounting bracket
400g
22g
60g
Mechanical service life 5 × 10
5
Switching operations
TECHNICAL DATA 9
8019972/1CS1/2022-07-20 | SICK O P E R A T I N G I N S T R U C T I O N S | TR10 Lock
35