Prerequisites
To mount on the machine, the safety switch and actuator must be put together.
Approach
b
Mount the actuator using 2 × M4 screws.
Complementary information
Mounting brackets are available for the actuator and safety locking device as acces‐
sories (see "Dimensional drawings of the mounting bracket", page 60).
5.5 Mounting the radius actuator
Important information
NOTICE
The actuator must not be used for guiding or used as a stop.
Prerequisites
To mount on the machine, the safety switch and actuator must be put together.
The actuator must be positioned perpendicularly to the guide slot before insertion.
Approach
1. Mount the actuator using 2 × M5 screws.
2. For larger radii, the actuator can be aligned using the adjustment screw.
Figure 19: Adjustment screw for alignment
1
Adjustment screw
Complementary information
Mounting brackets are available for the actuator and safety locking device as acces‐
sories (see "Dimensional drawings of the mounting bracket", page 60).
5.6 Mounting the escape release
Prerequisites
Hole in the mounting surface for the escape release (see "Escape release",
page 16).
Spacers with lengths of 30 mm or 50 mm for the escape release shaft (optional).
5 MOUNTING
26
O P E R A T I N G I N S T R U C T I O N S | TR110 Lock 8023119/15LY/2019-10-28 | SICK
Subject to change without notice