EasyManua.ls Logo

SICK TR110 Lock

SICK TR110 Lock
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
4
3
2
1
Figure 34: Internal circuitry: end connector for safe series connection
The 5-pin male connector of the last T-connector upstream of the safe evaluation unit is
the interface between the safe series connection and the safe evaluation unit.
12
3 4
5
Figure 35: Connection of the safe series connection (M12, 5-pin, A-coded, male connector)
Table 13: Pin assignment connection of the safe series connector (male connector, M12, 5-pin,
A-coded)
Pin Wire color
1)
Designation Description
1 Brown +24 V DC Voltage supply 24 V DC
2 White OSSD 1 OSSD 1 output
3 Blue 0 V Voltage supply 0 V DC
4 Black OSSD 2 OSSD 2 output
5 Gray RST Hardware reset connection
1)
Applies to the extension cables recommended as accessories.
2)
All switches of a chain can be reset simultaneously with the RST input (reset input). For this, a voltage of
24 V must applied to the RST input for at least 3 s.
If the RST input is not used, it must be connected to 0 V.
Further topics
"Accessories", page 63
6 ELECTRICAL INSTALLATION
34
O P E R A T I N G I N S T R U C T I O N S | TR110 Lock 8023119/15LY/2019-10-28 | SICK
Subject to change without notice