7.3.2.3 Teaching in switching window (Window Mode)
Overview
When the object is located within the taught-in switching window, the digital output is
active.
Approach
21
1.
Position the object at 1.
2. Press T2 pushbutton for 3 seconds until LED 1 and LED 2 flash simultaneously.
LED 1 and LED 2 flash alternately.
3.
Position the object at 2.
LED 1 and LED 2 flash alternately.
4. Press T2 for 1 second.
The switching points are taught in. The device automatically switches to normal
operation mode.
7.3.2.4 Teaching in background (Window Mode ±8%)
Overview
When the object is located either below the taught-in reflector -10mm (IO-Link: -8%) or
above the taught-in reflector +10mm (IO-Link: +8%), the digital output is active.
Approach
1
– 10 mm
+ 10 mm
1.
Position the background at 1.
2. Press T2 pushbutton for 3 seconds until LED 1 and LED 2 flash simultaneously.
LED 1 and LED 1 flash alternately.
3. Press T2 for 10 seconds until LED 1 and LED 2 stop flashing.
The background is taught in. The device automatically switches to normal opera‐
tion mode.
7.3.2.5 Adjusting the N/C contact and N/O contact
Approach
1. Press T2 pushbutton for 13 seconds until LED 1 and LED 2 flash alternately.
LED 1 flashes orange.
N/O contact: LED 2 lights up green.
N/C contact: LED 2 does not light up.
2. To change the setting, press T2 for 1 second.
3. Wait 10seconds.
N/C and N/O are adjusted. The device automatically switches to normal operation
mode.