7.3.3 Digital output 2 teach-in (UC40-xxxxxH only)
7.3.3.1 Factory settings of the digital output
N/O contact
Switching point at maximum operating range
7.3.3.2 Teaching in switching point (Single Point Mode)
Overview
When the object is located below the taught-in switching point, the digital output is
active.
Approach
Teaching in the switching point (distance to object as switching point)
1
1.
Position the object at 1.
2. Press T1 pushbutton for 3 seconds until LED 3 and LED 4 flash simultaneously.
LED 3 and LED 4 flash alternately.
3. Press T1 for 1 second.
The switching point is taught in. The device automatically switches to normal
operation mode.
Teaching in switching point (distance to object + 8% as switching point)
1.
Position the object at 1.
2. Press T1 pushbutton for 3 seconds until LED 3 and LED 4 flash simultaneously.
LED 3 and LED 4 flash alternately.
3. Press T1 for 3 seconds until LED 3 and LED 4 flash alternately again.
The switching point is taught in. The device automatically switches to normal
operation mode.
7.3.3.3 Teaching in switching window (Window Mode)
Overview
When the object is located within the taught-in switching window, the digital output is
active.
Approach
21
1.
Position the object at 1.
2. Press T1 pushbutton for 3 seconds until LED 3 and LED 4 flash simultaneously.
LED 3 and LED 4 flash alternately.
3.
Position the object at 2.
LED 3 and LED 4 flash alternately.