What to do if green and orange LEDs flash on SICK UM18-2 Pro?
- RrileymargaretOct 29, 2025
If the green and orange LEDs on your SICK Accessories are flashing at the same rate for 3 seconds, it could be due to several reasons. First, the teach point might be outside the permitted range, in which case you should check the teach distance and perform the teach again. Alternatively, the teach process might have failed because of interfering reflections or insufficient mounting distances when using multiple sensors. To resolve this, ensure the sensor detection zone is clear and shield any sources of interference. If you're using multiple sensors, make sure to observe the minimum mounting distances or operate the sensors in synchronization mode. Finally, if you're using an analog output, the taught-in distance between the scaling limits might be below 1 mm, so repeat the teach for wind...