Commissioning
Factory setting: Teach-in
1. Switch o the supply voltage.
2. Apply "M" to "MF".
3. Switch on the supply voltage and wait approximately 3 seconds until
both LEDs ash simultaneously.
4. The green LED ashes. The orange LED indicates the current setting:
On: Teach-in
O: Synchronization/multiplex mode
5. To change the setting, apply "M" to "MF" for approximately 1 second.
The orange LED changes its status.
6. After conguring, wait approximately 10 seconds until the green LED
stops ashing.
b The setting has been applied. The ultrasonic sensor is in normal
operational mode.
For additional information about synchronization/multiplex mode and
the minimum mounting distances without synchronization/multiplex mode,
see Page 16, Chapter 5.3.
7.3.2 Resetting the settings to the factory setting
1. Switch o the supply voltage.
2. Apply "M" to "MF".
3. Switch on the supply voltage and wait approximately 13 seconds until
both LEDs stop ashing.
4. Before switching o the supply voltage, disconnect "M" from "MF" in
order to apply the factory setting.
b All settings have been reset to the factory setting. The ultrasonic
sensor is in normal operational mode.