8014865/ZUJ3/2018-11-29 • © SICK AG • Subject to change without notice 45
Technical data
11.7 Ambient conditions
Protection class III
Electromagnetic compatibility
1)
EN 61000-6-2, EN 55011, Class A
EN 60947-5-2/-3
Ambient temperature range –25 °C … +70 °C
Storage temperature range –40 °C … +85 °C
Enclosure rating IP 67 according to EN 60529
1) Operation with lter setting "F00" is not permitted, as EMC faults may occur in this case.
Table 25: Ambient conditions
11.8 Structural design
Dimensions See Page 41, Chapter 11.1.
Weight Straight: 25 g
Angled: 30 g
Materials Housing: Nickel-plated brass
Ultrasonic transducer: polyurethane foam, glass epoxy resin
Connections Plug M12, 5-pin
Display Green LED: operation
Orange LED: on when switching/analog output is active
Table 26: Structural design

Table of Contents