mode.
7.4 Teach-in via multifunctional input
7.4.1 Setting pin 2 output (UC40-xxxxxH only)
Overview
The UC40-xxxxxH product type has a second output. For this output, it is possible to
choose between automatic current or voltage output and fixed current, voltage or digital
output. The desired output must be selected before the teach-in process.
With automatic selection of current or voltage output (factory setting), the device
checks the load at the analog output. Depending on the load, the device automatically
selects current or voltage output.
Approach
1. Switch off the supply voltage.
2. Ensure that connected hardware is not damaged by the 24 V output voltage.
3. Apply M at MF.
4. Switch on the supply voltage.
5. Wait for 6 seconds until LED 4 lights up and LED 3 flashes.
LED 4 lights up green
LED 4 flashes orange 1x: device automatically selects current or voltage output
(factory setting)
LED 4 flashes orange 2x: voltage output
LED 4 flashes orange 3x: current output
LED 4 flashes orange 4x: push-pull digital output
6. To change the setting, apply M at MF for 1second.
7. Wait 10seconds.
The pin 2 output is set. The device automatically switches to normal operation
mode.
7.4.2 Digital output1 teach-in
7.4.2.1 Factory settings of the digital output
N/O contact
Switching point at maximum operating range
7.4.2.2 Teaching in switching point (Single Point Mode)
Overview
When the object is located below the taught-in switching point, the digital output is
active.
Approach
Teaching in the switching point (distance to object as switching point)
1
1.
Position the object at 1.
OPERATION 7
8027772//2022-08-11 | SICK O P E R A T I N G I N S T R U C T I O N S | UC40
27
Subject to change without notice