2. Apply L+ at MF for 3seconds until both LED 1 and LED 2 are flashing simultane‐
ously.
LED 1 and LED 2 flash alternately.
3. Apply L+ at MF for 1second.
The switching point is taught in. The device automatically switches to normal
operation mode.
Teaching in switching point (distance to object + 8% as switching point)
1.
Position the object at 1.
2. Apply L+ at MF for 3seconds until both LED 1 and LED 2 are flashing simultane‐
ously.
LED 1 and LED 2 flash alternately.
3. Apply L+ at MF for 3seconds until both LED 1 and LED 2 flash alternately again.
The switching point is taught in. The device automatically switches to normal
operation mode.
7.4.2.3 Teaching in switching window (Window Mode)
Overview
When the object is located within the taught-in switching window, the digital output is
active.
Approach
21
1.
Position the object at 1.
2. Apply L+ at MF for 3seconds until both LED 1 and LED 2 are flashing simultane‐
ously.
LED 1 and LED 2 flash alternately.
3.
Position the object at 2.
LED 1 and LED 2 flash alternately.
4. Apply L+ at MF for 1second.
The switching points are taught in. The device automatically switches to normal
operation mode.
7.4.2.4 Teaching in background (Window Mode ±8%)
Overview
When the object is located either below the taught-in reflector -10mm (IO-Link: -8%) or
above the taught-in reflector +10mm (IO-Link: +8%), the digital output is active.
Approach
1
– 10 mm
+ 10 mm
1.
Position the background at 1.
7 OPERATION