Name Display Description Value
selec
tion
Display Initial
value
Description
ALM ALM Behavior during non-stable
distance measurement
CLP, HLD cLP X If the distance measurement
is not stable, the maximum
current/maximum voltage at
the analog output is issued.
hLd If the distance measurement
is not s
table, the most
recently valid current/voltage
value at the analog output is
maintained.
RST rSt Reset to factory settings NO, YES no X No reset.
YES Reset all values to factory set‐
tings with the exception of the
PNP/NPN selection.
DSP dSP Display settings ON, OFF on X Display shows display value in
cm.
oFF Display switches off 30 sec‐
onds aft
er an operating but‐
ton was last pressed.
DLY dLY Setting the time functions for
the switching output.
OFF, OFD,
OND, SHT
oFF X No time function activated.
oFd Switch-off delay, adjustable
from 0 … 999 ms
.
ond Switch-on delay, adjustable
from 0 … 999 ms.
Sht Single shot, adjustable from 0
… 999 ms.
NER nEr Distance assignment for 4 mA
or 0.04 V.
0 … 300 0 0
Value range 0 … 300
FAR FAr Distance assignment for
20 mA or 10 V.
0 … 300 300 300 Value range 0 … 300
Q_1 q_I Distance assignment for
sw
itching output Q1.
0 … 300 300 300 Value range 0 … 300
The factory setting of the analog output can be adjusted via the menu items ner and far:
T
he ner value defines the distance assignment for 4 mA / 0.04 V.
The far value defines the distance assignment for 20 mA / 10 V.
20 mA
(10 V)
4 mA
(0,04 V)
A
nalog output
Sensing
range
too far,
no target
too close
Distance
24 mA
(>11 V)
<2 mA
(0,02 V)
If the switching output is to be set via the menu, adjust entry Q_1.
CONFIGURATION 4
8020032.17U4 | SICK
Subjec
t to change without notice
11