2.2 Dimensional drawing
2
1
4.8
(0.19)
4
3
5
à ß 9
6
7
8
28.3 (1.11)
17
(0.67) 32.8 (1.29)
9
(0.35)
16
(0.63)
44.4 (1.75)
39.2 (1.54)
2.6
(0.1)
3.7 (0.12)
1.2
(0.05)
1.9
(0.07)
Ø 3.1
(0.12)
7
(0.28)
6 (0.24)
2.8 (0.11)
17.4 (0.69)
3
32.8 (1.29)
39.2 (1.54)
2.6
(0.1)
3.1
(0.12)
1.2
(0.05)
1.9
(0.07)
Ø 3.1
(0.12)
7 (0.28)
6 (0.24)
2.8 (0.11)
WTT190L-A2xxx WTT190L-A1xxx
WTT190L-A3xxx
1
Receiver
2
Sender
3
Connection
4
RUN button
5
(+) button
6
Output display (orange)
7
Stability display (green/red), laser off display (off)
8
Output display (orange)
9
(-/Q1) button
ß
Display
à
(SET) button
3 Commissioning
3.1 Check the application conditions:
Analog output:
Re
fer to TableTechnical data and Diagram H3, H4 for the accuracy specifications of the
analog output.
Switching output:
Check the application conditions: Adjust the sensing range and distance to the object
or background and the remission capability of the object according to the correspond‐
ing diagram [H1, H2] (x = sensing range, y = minimum distance between the object and
background in mm (object remission / background remission)). Remission: 6% = black,
90% = white (referring to standard white as per DIN 5033).
The minimum distance (= y) for background suppression can be read from diagram
[H15] as follows:
Example: x = 1,000 mm, y = 20 mm. That is, the background is suppressed at a dis‐
tance of > 20 mm from the sensor.