SR882 operation manual
~ 38 ~
► Press “SET” button to activate this function, then
“INTV ON” displays on the screen.
► Press “ESC” button to exit the menu or wait for 20
seconds to exit automatically, parameters are saved
automatically.
4.6.1 ISTAR Turn-on time for pump interval running function
Setup steps:
To select submenu ISTAR, “ISTAR 07:00” displays on
the screen.
► Press “ SET” button, parameter “07:00” blinks,
► Press “+” “-” button, to adjust turn-on time.
► Press “ESC” button to exit the menu or wait for 20
seconds to exit automatically, parameters are saved automatically.
4.6.2 IEND Turn-off time for pump interval running function
Setup steps:
To select submenu IEND, “IEND 18:00” displays on
the screen.
► Press “ SET” button, parameter “18:00” blinks,
► Press “+” “-” button, to adjust turn-off time.
► Press “ESC” button to exit the menu or wait for 20
seconds to exit automatically, parameters are saved automatically.
4.6.3 ISTP Pump interval time
Setup steps:
To select submenu ISTP, “ISTP 30” displays on the screen.
► Press “SET” button, parameter “30” blinks; factory
set is “30 minutes”
► Press “+” “-” button, to adjust time, adjustable range
2~ 60 minutes.
► Press “ESC” button to exit the menu or wait for 20
seconds to exit automatically, parameters are saved automatically.