EasyManua.ls Logo

Sidite SR882 - ISTAR Turn-On Time for Pump Interval Running Function; IEND Turn-Off Time for Pump Interval Running Function; ISTP Pump Interval Time

Sidite SR882
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SR882 operation manual
~ 38 ~
Press SET button to activate this function, then
“INTV ON” displays on the screen.
Press ESC button to exit the menu or wait for 20
seconds to exit automatically, parameters are saved
automatically.
4.6.1 ISTAR Turn-on time for pump interval running function
Setup steps:
To select submenu ISTAR, “ISTAR 07:00” displays on
the screen.
Press SET button, parameter 07:00 blinks,
Press + - button, to adjust turn-on time.
Press ESC button to exit the menu or wait for 20
seconds to exit automatically, parameters are saved automatically.
4.6.2 IEND Turn-off time for pump interval running function
Setup steps:
To select submenu IEND, “IEND 18:00” displays on
the screen.
Press SET button, parameter 18:00 blinks,
Press + - button, to adjust turn-off time.
Press ESC button to exit the menu or wait for 20
seconds to exit automatically, parameters are saved automatically.
4.6.3 ISTP Pump interval time
Setup steps:
To select submenu ISTP, “ISTP 30” displays on the screen.
Press SET button, parameter 30 blinks; factory
set is 30 minutes
Press + - button, to adjust time, adjustable range
2~ 60 minutes.
Press ESC button to exit the menu or wait for 20
seconds to exit automatically, parameters are saved automatically.

Table of Contents