SR882 operation manual
~ 40 ~
4.7.1 SFON Minimum turn-on temperature of tank
Setup steps:
To select submenu SFON, “SFON 50
o
C” displays on
the screen.
►Press “SET” button, parameter “50
o
C” blinks on the
screen.
►Press “+” “-” button, to adjust the turn-on
temperature, adjustable range:(10
o
C~OF-2
o
C),factory set is :50
o
C
► Press “ESC” button to exit the menu or wait for 20 seconds to exit automatically,
parameters are saved automatically.
4.7.2 SFOF Maximum turn-off temperature of tank
Setup steps:
To select submenu SFOF, “SFOF 55
o
C” displays on
the screen.
►Press “SET” button, parameter “55
o
C” blinks on the
screen.
►Press “+” “-” button, to adjust the turn-off temperature, adjustable range: (ON+2
o
C~80
o
C),factory set is :55
o
C
►Press “ESC” button to exit the menu or wait for 20 seconds to exit automatically,
parameters are saved automatically.
4.7.3 MAX3 Maximum turn-off temperature of solid fuel boiler
Setup steps:
To select submenu MAX3, “MAX3 60
o
C” displays on the screen.
►Press “SET” button, parameter “60
o
C” blinks on the
screen.
►Press “+” “-” button, to adjust the turn-off
temperature, adjustable range:(MIIN3+2
o
C~95
o
C),factory set is :60
o
C
► Press “ESC” button to exit the menu or wait for 20 seconds to exit automatically,
parameters are saved automatically.