UM353-1B Data Mapping
April 2012
6-15
L#G3Tag R Group 3 Tag 6 ASCII Char 45499+100(#-1)
L#G3P1T R Group 3 PB1 Tag 6 ASCII Char 45502+100(#-1)
L#G3P2T R Group 3 PB2 Tag 6 ASCII Char 45505+100(#-1)
L#G3SAT R Group 3 Switch Position A Tag 6 ASCII Char 45508+100(#-1)
L#G3SMT R Group 3 Switch Position M Tag 6 ASCII Char 45511+100(#-1)
L#G3F1T R Group 3 Feedback 1 Tag 6 ASCII Char 45514+100(#-1)
L#G3F0T R Group 3 Feedback 0 Tag 6 ASCII Char 45517+100(#-1)
L#G4Tag R Group 4 Tag 6 ASCII Char 45520+100(#-1)
L#G4P1T R Group 4 PB1 Tag 6 ASCII Char 45523+100(#-1)
L#G4P2T R Group 4 PB2 Tag 6 ASCII Char 45526+100(#-1)
L#G4SAT R Group 4 Switch Position A Tag 6 ASCII Char 45529+100(#-1)
L#G4SMT R Group 4 Switch Position M Tag 6 ASCII Char 45532+100(#-1)
L#G4F1T R Group 4 Feedback 1 Tag 6 ASCII Char 45535+100(#-1)
L#G4F0T R Group 4 Feedback 0 Tag 6 ASCII Char 45538+100(#-1)
L#G5Tag R Group 5 Tag 6 ASCII Char 40451+30(#-1)
L#G5P1T R Group 5 PB1 Tag 6 ASCII Char 40454+30(#-1)
L#G5P2T R Group 5 PB2 Tag 6 ASCII Char 40457+30(#-1)
L#G5SAT R Group 5 Switch Position A Tag 6 ASCII Char 40460+30(#-1)
L#G5SMT R Group 5 Switch Position M Tag 6 ASCII Char 40463+30(#-1)
L#G5F1T R Group 5 Feedback 1 Tag 6 ASCII Char 40466+30(#-1)
L#G5F0T R Group 5 Feedback 0 Tag 6 ASCII Char 40469+30(#-1)
Spares 40472-40480
Note: These Modbus groupings normally used for Variable Loop Integer Data with displays other than ODP
L#G6Tag R Group 6 Tag 6 ASCII Char 41201+30(#-1)
L#G6P1T R Group 6 PB1 Tag 6 ASCII Char 41204+30(#-1)
L#G6P2T R Group 6 PB2 Tag 6 ASCII Char 41207+30(#-1)
L#G6SAT R Group 6 Switch Position A Tag 6 ASCII Char 41210+30(#-1)
L#G6SMT R Group 6 Switch Position M Tag 6 ASCII Char 41213+30(#-1)
L#G6F1T R Group 6 Feedback 1 Tag 6 ASCII Char 41216+30(#-1)
L#G6F0T R Group 6 Feedback 0 Tag 6 ASCII Char 41219+30(#-1)
spares 41222-41230
Note: These Modbus groupings normally used for Static Loop Integer Data with displays other than ODP
L#G7Tag R Group 7 Tag 6 ASCII Char 42451+60(#-1)
L#G7P1T R Group 7 PB1 Tag 6 ASCII Char 42454+60(#-1)
L#G7P2T R Group 7 PB2 Tag 6 ASCII Char 42457+60(#-1)
L#G7SAT R Group 7 Switch Position A Tag 6 ASCII Char 42460+60(#-1)
L#G7SMT R Group 7 Switch Position M Tag 6 ASCII Char 42463+60(#-1)
L#G7F1T R Group 7 Feedback 1 Tag 6 ASCII Char 42466+60(#-1)
L#G7F0T R Group 7 Feedback 0 Tag 6 ASCII Char 42469+60(#-1)
L#G8Tag R Group 8 Tag 6 ASCII Char 42472+60(#-1)
L#G8P1T R Group 8 PB1 Tag 6 ASCII Char 42475+60(#-1)
L#G8P2T R Group 8 PB2 Tag 6 ASCII Char 42478+60(#-1)
L#G8SAT R Group 8 Switch Position A Tag 6 ASCII Char 42481+60(#-1)
L#G8SMT R Group 8 Switch Position M Tag 6 ASCII Char 42484+60(#-1)
L#G8F1T R Group 8 Feedback 1 Tag 6 ASCII Char 42487+60(#-1)
L#G8F0T R Group 8 Feedback 0 Tag 6 ASCII Char 42490+60(#-1)
spares 42493-42509
Note: These Modbus groupings normally used for Variable Loop Floating Point Data with displays other than ODP