Parameter List  09.02 
5-32  Siemens AG    6SE7087-6AK85-1AA0 
  Rectifier/Regenerating Unit    Operating Instructions 
PNU 
 
*
 
: Conf. 
    Par. 
OP1S parameter name 
 
Description 
Value range  
[phys. unit] 
Selection text 
Display 
Indices 
Factory- 
setting 
See 
Modify 
(access / 
status) 
P694 
* 
CB/TB Act Values 
Actual-value output over the serial interface of the CB and/or TB module 
Defines which parameter is to be transferred at which telegram address. 
 
Note: 
Word 1 should be set for status word 1 (r552=r968) 
If the value "0" is entered (factory settings from i002 to i016), the constant 
value "0" is passed on. 
 
i001  Word 01 of the (process data part of the) telegram 
i002  Word 02 of the (process data part of the) telegram 
... 
i016  Word16 of the (process data part of the) telegram 
 
PNU=2B6Hex; Type=O2; Scaling: 1Hex 
=
∧
 1 
0 to 999  16 
i001=968 
i002=0 
. . . 
i016=0 
3/    BR 
3/    B 
P695 
* 
CB/TB TlgOFFTime 
Telegram lag time of CB and TB 
If no correct telegram is received within the parameterized time a fault trip is 
set. 
Monitoring is carried out at intervals of 20 ms, therefore it is only appropriate 
to set values that are multiples of 20 ms. 
 
Description for setting: 
0:  no monitoring, no fault trip; must be parameterized for sporadic 
(non-cyclic) telegrams, e. g. operator panel OP at serial comm. 
interface 1. 
 
PNU=2B7Hex; Type=O2; Scaling: 1Hex 
=
∧
 1 ms 
0 to 6500 
[ms] 
- 
20 
3/    BR 
3/    BR 
P696  CB Parameter 1 
Communication board parameter 1. 
See manual of the used communication board. 
 
Parameter is only needed if a communication board is reported (P090 or 
P091 = 1) 
The communication board checks, if the set value is valid. If the value is not 
accepted, the fault message 80 is issued with fault value 5 
 
PNU=2B8Hex; Type=O2; Scaling: 1Hex 
=
∧
 1 
0 to 65535  - 
0 
3/  HBR 
3/  H 
P697  CB Parameter 2 
Communication board parameter 2 
see P696 
 
PNU=2B9Hex; Type=O2; Scaling: 1Hex 
=
∧
 1 
0 to 65535  - 
0 
3/  HBR 
3/H 
P698  CB Parameter 3 
Communication board parameter 3 
See P696 
 
PNU=2BAHex; Type=O2; Scaling: 1Hex 
=
∧
 1 
0 to 65535  - 
0 
3/  HBR 
3/  H 
P699  CB Parameter 4 
Communication board parameter 4 
See P696 
 
PNU=2BBHex; Type=O2; Scaling: 1Hex 
=
∧
 1 
0 to 65535  - 
0 
3/  HBR 
3/  H 
P700  CB Parameter 5 
Communication board parameter 5 
See P696 
 
PNU=2BCHex; Type=O2; Scaling: 1Hex 
=
∧
 1 
0 to 65535  - 
0 
3/  HBR 
3/  H 
P701  CB Parameter 6 
Communication board parameter 6 
See P696 
 
PNU=2BDHex; Type=O2; Scaling: 1Hex 
=
∧
 1 
0 to 65535  - 
0 
3/  HBR 
3/  H 