Technical data
7
Note
Siemens makes every attempt to ensure the accuracy of these specifications, but reserves the
right to change them at any time.
Note
EMC testing
EN 61326 (CE EMC) testing was conducted on the product while mounted in a metallic vessel
and wired using shielded cable, where the cable
shield was terminated in an EMC cable
gland at the device entry point. In addition, units with a flange process connec
tion were
mounted using a metallic gasket.
Power
Supply voltage 12-30 V DC any polarity, 2-wire current loop circuit, max. resistance
value 550 Ω @ 24 V DC
Measurement signal
4 20 mA or 20 4 mA according to NAMUR NE 43
Ex.approvals
Max.voltage which does not invalidate the intrinsically safe protection
of the sensor (probe): Um = 250 V AC
Environmental
location
indoor/outdoor
altitude
2000 m max.
ambient temperature
general purpose applications: 40 to +85 °C (40 to +185 °F)
hazardous locations: refer to applicable certificate
relative humidity
suitable for outdoors
installation category
I
pollution degree
4