7SR242 Duobias Commissioning & Maintenance Guide
The copyright and other intellectual property rights in this document, and in any model or article produced from it
(and including any registered or unregistered design rights) are the property of Siemens Protection Devices
Limited. No part of this document shall be reproduced or modified or stored in another form, in any data retrieval
system, without the permission of Siemens Protection Devices Limited, nor shall any model or article be
reproduced from this document unless Siemens Protection Devices Limited consent.
While the information and guidance given in this document is believed to be correct, no liability shall be accepted
for any loss or damage caused by any error or omission, whether such error or omission is the result of
negligence or any other cause. Any and all such liability is disclaimed.
©2010 Siemens Protection Devices Limited
7SR242 Duobias
Multi-Function 2-Winding Transformer Protection Relay
Document Release History
This document is issue 2010/02. The list of revisions up to and including this issue is:
2010/06 Defect Report Form revised
2010/02 Document reformat due to rebrand
2010/02 Third issue. Software revision 2662H80001 R4c-3
2008/07 Second issue. Software revision 2662H80001R3d-2c.
2008/05 First issue
Software Revision History
2010/02 2662H80001 R4c-3 Revisions to: VT ratio settings, 87BD 1
st
bias slope limit setting
increments, CB fail function, LED CONFIG menu, DATA STORAGE
menu.
Added: Open circuit detection (46BC), CONTROL MODE menu,
Close circuit supervision (74CCS), Measured earth fault undercurrent
(37G), Pulsed output contacts.
2008/07 2662H80001R3d-2c. Demand metering. Optional DNP3.0 data comms.
2008/05 2662H80001R3-2b First Release

Table of Contents

Questions and Answers:

Siemens 7SR242 Duobias Specifications

General IconGeneral
BrandSiemens
Model7SR242 Duobias
CategoryProtection Device
LanguageEnglish

Summary

Document Release History

Software Revision History

Section 1: Common Functions

1.1 Overview

Outlines the purpose and scope of commissioning tests for the relay.

1.2 Before Testing

Covers essential pre-testing procedures including safety, equipment, and precautions.

1.3 Tests

Details the types of tests: inspection, secondary injection, primary injection, and commissioning.

1.4 AC Energising Quantities

Describes the procedure for checking AC voltage and current measurements.

1.5 Binary Inputs

Explains how to test and monitor the relay's binary inputs.

1.6 Binary Outputs

Details the testing of the relay's binary output contacts.

1.7 Relay Case Shorting Contacts

Describes the procedure for checking the relay case shorting contacts.

Section 2: Protection Functions

2.1 Biased Differential (87BD, 87HS)

Procedures for testing the biased differential protection function.

2.2 Derived Earth fault (50N,51N)

Procedures for testing derived earth fault protection.

2.3 Measured Earth fault (50G, 51G)

Procedures for testing measured earth fault protection.

2.4 Restricted Earth fault (64H)

Procedures for testing restricted earth fault protection.

2.5 Open Circuit (46BC)

Procedures for testing the open circuit detection function.

2.6 Negative Phase Sequence Overcurrent (46NPS)

Procedures for testing negative phase sequence overcurrent.

2.7 Undercurrent (37, 37G)

Procedures for testing undercurrent protection functions.

2.8 Thermal Overload (49)

Procedures for testing thermal overload protection.

2.9 Under/Over Voltage (27/59)

Procedures for testing under/over voltage protection.

2.10 Neutral Over Voltage (59N)

Procedures for testing neutral overvoltage protection.

2.11 Under/Over Frequency (81)

Procedures for testing under/over frequency protection.

2.12 Overfluxing (24)

Procedures for testing the overfluxing detection function.

Section 3: Supervision Functions

3.1 CB Fail (50BF)

Details testing for the Circuit Breaker Fail protection function.

3.2 Trip/Close Circuit Supervision (74TCS, 74CCS)

Explains testing for trip and close circuit supervision.

3.3 Magnetising Inrush Detector (81HBL2)

Covers testing of the magnetising inrush detection function.

3.4 Overfluxing Detector (81HBL5)

Describes testing for the overfluxing detection function.

Section 4: Control & Logic Functions

4.1 Quick Logic

Discusses testing of logic equations and their impact on other functions.

Section 5: Testing and Maintenance

5.1 Periodic Tests

Outlines recommended checks during normal maintenance.

5.2 Maintenance

Guidance on relay failure indication and contacting Siemens support.

5.3 Troubleshooting

A guide for diagnosing and resolving common relay issues.

5.4 Defect Report Form

Related product manuals