Repair Documentation
Description of procedure:
DIAGNOSIS
Visually check the status of the IrDa module. Watch for dry solder joints.
Use a reference infrared port (eg. from a notebook) to check the IrDa
function. If the notebook recognizes the S35, the infrared function is ok.
REPAIR BY COMPONENT CHANGE
Use hot air to remove defective infrared module.
Avoid excessive heat!
Watch surrounding components!!
Resolder new module afterwards
REPAIR BY SW-BOOTING
Not possible!
TEST
Retest handset after repair.