Installation, connecting up and commissioning
5.3 Connecting the CP to Ethernet
CP 343-1 Lean
Manual, 10/2012, C79000−G8976−C198−07
35
,QWHJUDWHGVZLWFKZLWK
H[WHUQDOFRQQHFWRUV
6ZLWFK 6ZLWFK
6ZLWFK
&3
Figure 5-2 Connecting switches
Note
MRP configuration
With an MRP configuration, keep to the setup guidelines for MRP.
You will find examples of network attachments in the general Part A of this manual, see
/1/ (Page 60).