Product overview
3
3.1 New functions
This section contains an overview of the most important new firmware functions of the CPU
compared to the predecessor CPU (V2.9).
New functions of the CPU in firmware version V3.0
New functions Applications Customer benefits
Communication of the CPU
Network Management Protocol
SNMP
A simple configuration option is available for
using the SNMP services. For new configura
tions, this is disabled by default in terms of
"Security-by-Default".
Can be enabled/disabled in the CPU proper
ties. Community strings can be configured.
OPC UA server – Reading the
diagnostic status of the own
address space
By using the OPC UA instruction for reading
("OPC_UA_ReadList"), the own namespace of
the OPC UA Server can be accessed.
This allows you to read out the following
statuses and react to them in the user program:
Status of the own OPC UA server
Status of the connections of OPCUA clients
Status of the session
Status of subscriptions
This allows connection problems to be
quickly detected, for example, and plant
availability to be increased.
OPC UA server – Time stamping
of the source time of nodes
By using the OPC UA instruction for writing
("OPC_UA_WriteList") it is possible to change
the "SourceTimestamp" as well as the status
code of an OPC UA variable (node).
Distinction between the "source" and "serv
er" time possible
OPC UA server – Increase of the
quantity structures
The following quantity structures have been
increased:
Possible number of nodes in the server
interface
Maximum possible number of subscriptions
per session
For subscription, the recommendation for
observed values was increased.
Further applications for CPUs as OPC UA
servers
Web server of the CPU
New Web API methods: Many new API methods extend your access
options to the CPU via the Web API.
Additional applications for the web server
Dynamic management of certi
ficates
The web server certificate for HTTPS communic
ation can now also be managed via the OPC UA
GDS mechanism, without separate download of
the hardware configuration.
Flexible certificate management
11
CPU 1512SP-1 PN (6ES7512-1DM03-0AB0)
Equipment Manual, 11/2022, A5E33591411-AE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CPU 1512SP-1 PN and is the answer not in the manual?

Siemens CPU 1512SP-1 PN Specifications

General IconGeneral
BrandSiemens
ModelCPU 1512SP-1 PN
CategoryIndustrial Equipment
LanguageEnglish