NOTE
You must provide covers for unused BusAdapter interfaces. You can find the article no. of the
cover in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/en/view/58649293) in the "Accessories/spare
parts" section.
3.3 Firmware functions
Functions
The CPU supports the following functions:
Function Description Additional information
Integrated system
diagnostics
The system automatically generates the messages for the
system diagnostics and outputs these messages via a
programming device/PC, HMI device, the web server or
the integrated display. System diagnostics information is
also available when the CPU is in STOP mode.
Diagnostics function manual
(https://support.automation.siemens.
com/WW/view/en/59192926)
Integrated web server The web server lets you access the CPU data by means of
a network. Evaluations, diagnostics, and modifications
are thus possible over long distances. Monitoring and
evaluation is possible without STEP7, only a web
browser is required. Note that you must take appropriate
measures to protect the CPU from compromise (such as
restricting network access, using firewalls).
Web server function manual
(https://support.automation.
siemens.
com/WW/view/en/59193560)
Security with SIMATIC S7 control
lers system manual
(https://support.industry.siemens.
com/cs/ww/en/view/90885010)
Integrated trace
functionality
Trace functionality supports you in troubleshooting
and/or optimizing the user program.
You record device tags and evaluate the recordings with
the trace and logic analyzer function. Tags are, for
example, drive parameters or system and user tags of a
CPU.
The device saves the recordings. You can read out and
permanently save the recordings with the configuration
system (ES), if required. The trace and logic analyzer
function is therefore suitable for monitoring highly
dynamic processes.
The trace record can also be displayed through the web
server.
With the project trace, you record the variables of mul
tiple devices within a project, for example, a controller
and a drive.
With the long-term trace, you record up to 64 different
tags for each cycle in a .csv file over a long period (e.g.
hours, days).
Using the trace and logic analyzer
function function manual
(https://support.automation.siemens.
com/WW/view/en/64897128)
15
Product overview
3.3 Firmware functions
CPU 1512SP-1 PN (6ES7512-1DM03-0AB0)
Equipment Manual, 11/2022, A5E33591411-AE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CPU 1512SP-1 PN and is the answer not in the manual?

Siemens CPU 1512SP-1 PN Specifications

General IconGeneral
BrandSiemens
ModelCPU 1512SP-1 PN
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals