List of Parameters
Parameters
1-395
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description: Setting parameter for the run-time group in which the instance NCM 1 of the numeric comparator is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance NCM 1 within the run-time group set in p20322.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source for set input S and reset input R of instance RSR 2 of the RS flipflop.
Index: [0] = Set S
[1] = Reset R
Description: Display parameter for output Q of instance RSR 2 of the RS flipflop
Description: Display parameter for inverted output QN of instance RSR 2 of the RS flipflop.
Description: Setting parameter for the run-time group in which instance RSR 2 of the RS flipflop is to be called.
Value: 1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
p20322 NCM 1 run-time group / NCM 1 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
5 9999 9999
p20323 NCM 1 run sequence / NCM 1 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
0 32000 830
p20324[0...1] BI: RSR 2 inputs / RSR 2 inputs
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
- - 0
r20325 BO: RSR 2 output Q / RSR 2 output Q
Access level: 3 Calculated: - Data type: Unsigned32
Unit: - Scaling: - Data set: -
r20326 BO: RSR 2 inverted output QN / RSR 2 inv outp QN
Access level: 3 Calculated: - Data type: Unsigned32
Unit: - Scaling: - Data set: -
p20327 RSR 2 run-time group / RSR 2 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
1 9999 9999