Function diagrams
Overview
2-450
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Fig. 2-10 1710 – Vector control, current control
- 1710 -
Function diagram
87654321
FP_1710_97_54.vsd
Overviews
G120 CU230P-2
29.10.2009 V4.3
Vector control, current control
f
|y|
Iq
M
f
|y|
+
+
+
+
Iq
M
K
P
p1764 p1767
+
+
+
+
U_soll
+
[1700.5]
U_Winkel
[1700.1]
[1700.8]
[6722.1]
[6723.4]
[6724.4]
[6710] Current setpoint filter
Field-weakening
controller
Field-weakening
characteristic
Current calculation
[6722] Field-weakening characteristic, Id setpoint
[6723] Field weakening control, flux controller for induction motors
(p0300 = 1)
[6724] Field weakening controller for synchronous motors (p0300 = 2)
n_pre-control
n_model
iq controller
id controller
[6714] Current controller
Transformation
Current
model
Motor model
(Observer)
[6730] Interface to the Power Module for an induction motor (p0300 = 1)
[6731] Interface to the Power Module for a synchronous motor (p0300 = 2)
I_phase actual value
V_phase actual value
r0079
M_set total [Nm]
V_output max [Veff]
r0071
r0075
Id_set [Aeff]
r0078
Iq_act [Aeff]
r0076
Id_act [Aeff]
r0072
V_output [Veff]
r0070
Vdc act val [V]
r0074
Modulat_depth [%]
r0066
f_outp [Hz]
r0077
Iq_set [Aeff]
Efficiency opt.
0 ... 100 [%]
p1580 [D] (80)
M_set static
-200.0 ... 200.0 [%]
p1610 [D] (50.0)
M_suppl_accel
0.0 ... 200.0 [%]
p1611 [D] (0.0)
I_ctrl Kp
p1715
I_ctrl Tn
p1717
I_ctrl Kp
p1715
I_ctrl Tn
p1717
f_Slip [Hz]
r0065
Flux setpoint
50.0 ... 200.0 [%]
p1570 [D] (100.0)
V_set