Article number 6DL1155-6AU00-0PM0
● ACTIVE-LED (active IM in redundant
configuration)
Yes; Green LED
● Monitoring of the supply voltage (PWR-LED)
Yes; green PWR LED
● Connection display LINK TX/RX
Yes; 2x green link LEDs on BusAdapter
Potential separation
between PROFINET and all other circuits Yes; 1500 V AC
between supply and all other circuits Yes; Type tested with 1 500 V DC
Permissible potential difference
between different circuits Safety extra low voltage SELV
Isolation
Isolation tested with 1 500 V DC/1 min, type test
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.
-40 °C
● horizontal installation, max.
70 °C
● vertical installation, min.
-40 °C
● vertical installation, max.
60 °C
Dimensions
Width 50 mm
Height 138 mm
Depth 89 mm
Weights
Weight, approx. 192 g; without BusAdapter
Supplemental information on the address space for each operating mode
The size of user data attachment of the I/O modules depends on the type (1 byte if only input
or output address space are allocated, or 2 bytes if both address spaces are allocated). You
can determine the allocated address space from the technical specifications in the manuals
of the I/O modules.
Configuration Operating mode Address space
Redundant IM on H system R1 mode 1440 bytes (of which I/O: 1432 bytes for the address space and
PROFINET user data attachment of the I/O modules, 8 bytes
for PROFINET user data attachment of the IM)
Single IM on H system S2 mode 1000 bytes (of which I/O: 996 bytes for the address space and
PROFINET user data attachment of the I/O modules, 4 bytes for
PROFINET user data attachment of the IM)
Single IM on single CPU S1 mode 1000 bytes with CiR capability, or 1440 bytes without CiR capability
(including I/O: 996/1436 bytes for the address space and PROFI‐
NET user data attachment of the I/O modules, 4 bytes for PROFI‐
NET user data attachment of the IM)
Technical specifications
Interface Module IM 155-6 PN HA (6DL1155-6AU00-0PM0)
Manual, 05/2017, A5E39262148-AA 27