HiPath HG 1500 board
lan2de.c02
A31003-K5020-S100-6-7620
Service Manual
2-9
For internal use only Installation
LAN adapter cable (U.S. only)
Contact is established between the LAN and RJ45 via a CHAMP adapter cable. The adapter is
connected to the CHAMP socket on the rear of the backplane which is assigned to the HG 1500
slot. Both the adapter cable and the connector are shielded.
Figure 2-5 LAN adapter cable (U.S. only)
Table 2-8 Assignment of the SIPAC-RJ45 LAN adapter
SIPAC connec-
tor
RJ45 socket Signal
B1 1 TDP
C2 2 TDN
B3 4 TT1
C4 5 TT2
B5 3 RDP
C6 6 RDN
B7 7 RT1
C8 8 RT2
10/100 Base-T
10 Base-T
female
male