Initial startup of HiPath HG 150
0
lan2de.c03
A31003-K5020-S100-6-7620
Service Manual
3-1
For internal use only Startup
3 Startup
3.1 Initial startup of HiPath HG 1500
Note
Windows 3.11 is no longer supported.
3.1.1 Initial startup: Remote via modem
Prerequisites
The feature is only available as of Hicom Rel. 3 SMR-E with Assistant Office P30300-
P1584-A1-02 and SMR-11 HG1500. Hicom must be configured for remote adminis-
tration and HiPath HG 1500 must be in the default state (default customer database).
Step Task
1. Using Assistant E, read out the contents of the board using the Restart/
Reload option "Maintenance". Then enter an
existing
call number as an
extension in the numbering plan. (Recommendation: Pro -748, Com -686,
Point -69)
2. Transfer the changes into Hicom using "Transfer data"
3. The following changes will automatically be made in the customer data-
base for HiPath HG 1500:
- the ISDN peer "remote default" will be set with the following parameters:
IP address: 10.186.237.64
CHAP user ID: 31994 (Host = On)
CHAP password: 31994
V.34 peer: Yes
- the ISDN2 interface is assigned the IP address 10.186.237.63
- the IP address 10.186.237.64 is assigned administration rights
4. A new dial-up networking connection with the following data is generated
on the PC (here W98):
Connect via: Standard 19200 bps modem (dependent on the modem in
use)
Type of Dial-Up Server> PPP Windows 95, Windows NT 3.5
Logon to the network: No
Activate software compression: No
Request encrypted password: No
NetBEUI: No
IPX/SPX: No
Define IP address: 10.186.237.64
Use IP header compression: No
Use the standard GW in the remote network: No