Initial startup of HiPath HG 150
0
lan2de.c03
A31003-K5020-S100-6-7620
Service Manual
3-5
For internal use only Startup
3.2.1 Configuration HiPath HG 1500
3.2.2 Configuring the NGK 100 gatekeeper
Relevant options under "Settings
"
Step Task
1. Under
Voice Clients -> Gatekeeper
:
Enter the IP address of the PC with the gatekeeper,
enable gatekeeper support and configure the prefix.
2. Under
Voice Clients -> H.323 Clients
:
Configure the clients with a gatekeeper connection using IP address
"255.255.255.255".
Clients without a gatekeeper connection must be configured with the fixed
IP addresses of the corresponding PCs.
3. Under
Voice Clients -> Xpress Clients
:
There are no additional aspects to be noted here.
Step Task
1. Capacity Characteristics:
Set the
IRQ interval
to
0
if the registered endpoints do not need to be cy-
clically polled, e.g. when using RAS connections for teleworking.
2. Call and Registration Policy:
Accept Call
must be enabled.
Set
All Endpoints
or
Predefined endpoints
.
3. Routing Mode:
Set
Gatekeeper Routed
or
Direct Routed
.