Integrating various network topologies
Additional information For internal use only
A31003-K5020-S100-6-7620
5-2 Service Manual
lan2de.c05
load-bearing capacity of the network, structured (star) cabling is becoming increas-
ingly popular. The integrated HiPath HG 1500 can only be connected via a hub or
switch.
Figure 5-2 10 Base2 cabling
Note
The coaxial cable must have terminating resistors at both ends.
No spur lines are permitted in the coaxial cable.
The T units must be positioned directly on the terminals.
Max. length of the LAN is 185 m.
Hicom 150 E Office
Hicom 150 H
PC
PC
PC
LAN
PC
HUB