Technical Information
Power supply unit Primary: 230V AC, 30 VA
Secondary:24 V DC stabilised
5 V DC stabilised
Current consumption: 60mA Primary
Material: PS/Polystorol
Protection category: IP 40
Dimensions: 150 x 80 x 55 mm
Distribution frame
module
4 conference microphone inputs with respective flow-operated am-
plifiers and separate audio level-related automatic shutdown device
Mute electronic shutdown device for all channels
1 loudspeaker unit connection with power supply
Output connector for 2 distribution frame modules or radio micro-
phones
Regulator for microphone sensitivity
Regulator for background noise in the room
Conference loudspeaker Amplifying capacity: 7 Watt
Frequency domain: 100 Hz - 16 kHz
NF-input impedance: 10 K
Current consumption: 30/170mA (idle/load)
Connection cable: 2 m with "Miniwestern" plug
Dimensions: 160 x 98 x 95 mm
Colour: manganese
Weight: approx. 450 g
Conference microphone Acoustic mode of operation, pressure receiver
Frequency domain: 100 Hz - 7 kH
Characteristics: Kidney
Output impedance: 10 K
Voltage supply: 5 V DC
Current consumption: 6 mA
Connection cable: 0.80 m
Dimensions: 25 x 68 x 77 mm
Colour: manganese
Conference clip-on mi-
crophone
Acoustic mode of operation, pressure receiver
Frequency domain: 100 Hz - 7 kHz
Characteristics: Kidney
Output impedance: 10 K
Voltage supply: 5 V DC
Current consumption: 4 mA
Connection cable: 1.40 m
Dimensions housing: 65 x 46 x 16 mm