EasyManuals Logo

Siemens RUGGEDCOM RMC20 User Manual

Siemens RUGGEDCOM RMC20
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
Technical Specifications
4.3Operating Environment
4.3 Operating Environment
Parameter Range Comments
Ambient Operating
Temperature
a
-40 to 85 °C
(-40 to 185 °F)
Measured from a 30 cm (12 in) radius
surrounding the center of the enclosure.
Ambient Relative Humidity 5% to 95% Non-condensing
Ambient Storage Temperature -40 to 85 °C
(-40 to 185 °F)
a
Typical. May change based on which fiber optic transceivers are installed. For more information, refer to
"Fiber Optic Port Specifications (Page 23)".
4.4 Mechanical Specifications
Weight 0.68 kg (1.5 lbs)
Ingress Protection IP30
Enclosure 21 AWG Galvanized Steel
4.5 Dimension Drawings
Note
All dimensions are in millimeters, unless otherwise stated.
70.7
92.8
80.1
73.7
62.2
58.4
109.0
99.3
Figure4.1 Overall Dimensions
24
RUGGEDCOM RMC20
Installation Manual, 04/2021, C79000-G8976-1007-10