Certification
6.2EMC and Environmental Type Tests
Test Description Test Levels Severity
Levels
AC Power
ports
±4 kV 4
Earth
ground ports
±4 kV 4
Signal ports ±4 kV line-to-earth,
±2 kV line-to-line
4
DC Power
ports
±2 kV line-to-earth,
±1 kV line-to-line
3
IEC
61000-4-5
Surge
AC Power
ports
±4 kV line-to-earth,
±2 kV line-to-line
4
Signal ports 10 V 3
DC Power
ports
10 V 3
AC Power
ports
10 V 3
IEC
61000-4-6
Induced (Conducted) RFI
Earth
ground ports
10 V 3
IEC
61000-4-8
Magnetic Field Enclosure
ports
40 A/m continuous,
1000 A/m for 1 s
DC Power
ports
30% for 0.1 s, 60% for
0.1 s, 100% for 0.05 s
IEC
61000-4-29
30% for 1 period,
60% for 50 periods
IEC
61000-4-11
Voltage Dips and Interrupts
AC Power
ports
100% for 5 periods,
100% for 50 periods
Signal ports 2.5 kV common, 1 kV
differential mode @ 1 MHz
3
DC Power
ports
2.5 kV common, 1 kV
differential mode @ 1 MHz
3
IEC
61000-4-12
Damped Oscillatory
AC Power
ports
2.5 kV common, 1 kV
differential mode @ 1 MHz
3
Signal ports 30 V Continuous,
300 V for 1 s
4IEC
61000-4-16
Mains Frequency Voltage
DC Power
ports
30 V Continuous,
300 V for 1 s
4
IEC
61000-4-17
Ripple on DC Power Supply DC Power
ports
10% 3
Signal ports 2 kVAC (Fail-
Safe Relay output)
DC Power
ports
1.5 kVDC
Dielectric Strength
AC Power
ports
2 kVDC
Signal ports 5 kV (Fail-Safe
Relay Output)
IEC 60255-5
HV Impulse
DC Power
ports
5 kV
28
RUGGEDCOM RS8000T