Technical Specifications
5.2Failsafe Alarm Relay Specifications
5.2 Failsafe Alarm Relay Specifications
Hazardous Environments
Maximum Switching Voltage Rated Switching Current Isolation
30 VDC 2 A 5.0 kVAC
a
between
coil and contacts
1.0 kVAC
a
between contacts
250 VAC 2 A 5.0 kVAC
a
between
coil and contacts
1.0 kVAC
a
between contacts
a
50 to 60 Hz for 1 minute
Non-Hazardous Environment
Maximum Switching Voltage Rated Switch-
ing Current
Isolation
30 VDC 2 A 5.0 kVAC
a
between coil and contacts
1.0 kVAC
a
between contacts
250 VAC 2 A 5.0 kVAC
a
between coil and contacts
1.0 kVAC
a
between contacts
a
50 to 60 Hz for 1 minute
5.3 Supported Networking Standards
Standard 10 Mbps Ports 100 Mbps
Ports
1000 Mbps
Ports
Description
IEEE 802.1D
ü ü ü
MAC Bridges, Spanning Tree Pro-
tocol (STP)
IEEE 802.1p
ü ü ü
Class of Service (CoS)
IEEE 802.1Q
ü ü ü
VLAN (Virtual LAN) Tagging
IEEE
802.1Q-2005
ü ü ü
Multiple Spanning Tree Protocol
(MSTP)
IEEE 802.1w
ü ü ü
Rapid Spanning Tree Protocol
(RSTP)
IEEE 802.1x
ü ü ü
Port-Based Network Access Con-
trol
IEEE 802.3
ü
10Base-T
IEEE 802.3ab
ü
1000Base-Tx
IEEE 802.3ad
ü
Link Aggregation
IEEE 802.3u
ü
100Base-TX
IEEE 802.3x
ü ü ü
Flow Control
IEEE 802.3z
ü
1000Base-LX
26
RUGGEDCOM RSG910C
Installation Manual, 02/2020, C79000-G8976-1405-06

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM RSG910C and is the answer not in the manual?

Siemens RUGGEDCOM RSG910C Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM RSG910C
CategorySwitch
LanguageEnglish

Related product manuals