Certification
6.2EMC and Environmental Type Tests
EN50121-4
Railway applications – Electromagnetic Compatibility – Emission and Immunity
of the Signaling and Telecommunications Apparatus
EN50121-3-2
Railway applications – Electromagnetic Compatibility – Rolling Stock Apparatus
EN 50155
Railway applications – Rolling stock – Electronic equipment
6.2 EMC and Environmental Type Tests
The RUGGEDCOM RSG910C has passed the following Electromagnetic Compatibility
(EMC) and environmental tests.
EMC Type Tests
Test Description Test Levels Severi-
ty Levels
Enclosure
Contact
± 8 kV 4IEC
61000-4-2
ESD
Enclosure Air ± 15 kV 4
IEC
61000-4-3
Radiated RFI Enclo-
sure Ports
20 V/m
Signal Ports ± 4 kV @ 2.5 kHz, 5 kHz 4
DC Pow-
er Ports
± 4 kV @ 2.5 kHz, 5 kHz 4
AC Pow-
er Ports
± 4 kV @ 2.5 kHz, 5 kHz 4
IEC
61000-4-4
Burst (Fast Transient)
Earth
Ground Ports
± 4 kV @ 2.5 kHz, 5 kHz 4
Signal Ports ± 4 kV Line-to-Ground
± 2 kV Line-to-Line
4
DC Pow-
er Ports
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
3
IEC
61000-4-5
Surge
AC Pow-
er Ports
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
4
Signal Ports 10 V 3
DC Pow-
er Ports
10 V 3
AC Pow-
er Ports
10 V 3
IEC
61000-4-6
Induced (Conducted) RFI
Earth
Ground Ports
10 V 3
IEC
61000-4-8
Magnetic Field Enclo-
sure Ports
100 A/m Continuous
1000 A/m for 1 s
36
RUGGEDCOM RSG910C
Installation Manual, 02/2020, C79000-G8976-1405-06

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM RSG910C and is the answer not in the manual?

Siemens RUGGEDCOM RSG910C Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM RSG910C
CategorySwitch
LanguageEnglish

Related product manuals