EasyManua.ls Logo

Siemens RUGGEDCOM RSG910C - EMC and Environmental Type Tests

Siemens RUGGEDCOM RSG910C
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Certification
6.2EMC and Environmental Type Tests
EN50121-4
Railway applications – Electromagnetic Compatibility – Emission and Immunity
of the Signaling and Telecommunications Apparatus
EN50121-3-2
Railway applications – Electromagnetic Compatibility – Rolling Stock Apparatus
EN 50155
Railway applications – Rolling stock – Electronic equipment
6.2 EMC and Environmental Type Tests
The RUGGEDCOM RSG910C has passed the following Electromagnetic Compatibility
(EMC) and environmental tests.
EMC Type Tests
Test Description Test Levels Severi-
ty Levels
Enclosure
Contact
± 8 kV 4IEC
61000-4-2
ESD
Enclosure Air ± 15 kV 4
IEC
61000-4-3
Radiated RFI Enclo-
sure Ports
20 V/m
Signal Ports ± 4 kV @ 2.5 kHz, 5 kHz 4
DC Pow-
er Ports
± 4 kV @ 2.5 kHz, 5 kHz 4
AC Pow-
er Ports
± 4 kV @ 2.5 kHz, 5 kHz 4
IEC
61000-4-4
Burst (Fast Transient)
Earth
Ground Ports
± 4 kV @ 2.5 kHz, 5 kHz 4
Signal Ports ± 4 kV Line-to-Ground
± 2 kV Line-to-Line
4
DC Pow-
er Ports
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
3
IEC
61000-4-5
Surge
AC Pow-
er Ports
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
4
Signal Ports 10 V 3
DC Pow-
er Ports
10 V 3
AC Pow-
er Ports
10 V 3
IEC
61000-4-6
Induced (Conducted) RFI
Earth
Ground Ports
10 V 3
IEC
61000-4-8
Magnetic Field Enclo-
sure Ports
100 A/m Continuous
1000 A/m for 1 s
36
RUGGEDCOM RSG910C
Installation Manual, 02/2020, C79000-G8976-1405-06