RUGGEDCOM RX5000
Installation Guide
Chapter 6
Certification
EMC and Environmental Type Tests 35
Test Description Test Levels
Severity
Levels
AC Power ports 10V 3
Earth ground ports 10V 3
100 A/m
IEC 61000-4-8 Magnetic Field Enclosure Ports
1000 A/m for 1 s 5
DC Power ports
30% for 0.1 s, 60% for
0.1 s, 100% for 0.05 s
IEC 61000-4-29 Voltage Dips & Interrupts
AC Power ports 30% for 1 period, 60% for 50 periods
IEC 61000-4-11 Voltage Dips & Interrupts AC Power ports
100% for 5 periods,
100% for 50 periods
Signal ports
2.5 kV common, 1 kV
differential mode @1 MHz
3
DC Power ports
2.5 kV common, 1 kV
differential mode @1MHz
3
IEC 61000-4-12 Damped Oscillatory
AC Power ports
2.5 kV common, 1 kV
differential mode @1MHz
3
Signal ports 30 V Continuous, 300 V for 1 s 4
IEC 61000-4-16 Mains Frequency Voltage
DC Power ports 30 V Continuous, 300 V for 1 s 4
IEC 61000-4-17 Ripple on DC Power Supply DC Power ports 10% 3
Signal ports 2 kV (Fail-Safe Relay output)
DC Power ports 2 kVDielectric Strength
AC Power ports 2 kV
Signal ports 5 kV (Fail-Safe Relay output)
DC Power ports 5 kV
IEC 60255-5
HV Impulse
AC Power ports 5 kV
a
Siemens-specified severity levels
IEEE 1613 EMC Type Tests
NOTE
The RUGGEDCOM RX5000 meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper ports.
Description Test Levels
Enclosure Contact +/-2 kV, +/-4 kV, +/- 8 kVESD
Enclosure Air +/-4 kV, +/-8 kV, +/-15 kV
Radiated RFI Enclosure ports 35 V/m
Signal ports +/- 4 kV @ 2.5 kHzFast Transient
DC Power ports +/- 4 kV