RUGGEDCOM RX5000
Installation Guide
Chapter 4
Technical Specifications
Failsafe Relay Specifications 27
Technical Specifications
This section provides important technical specifications related to the device and available modules.
CONTENTS
Section4.1, “Failsafe Relay Specifications”
Section4.2, “Operating Environment”
Section4.3, “Mechanical Specifications”
Section4.1
Failsafe Relay Specifications
Maximum Switching Voltage Rated Switching Current Isolation
30 VDC 2 A, 60 W
125 VDC 0.24 A, 30 W
125 VAC 0.5 A, 62.5 W
220 VDC 0.24 A, 60 W
250 VAC 0.25 A, 62.5 W
1500 V
rms
for 1 minute
Section4.2
Operating Environment
Parameter Range Comments
Ambient Operating Temperature -40 to 85 °C
(-40 to 185 °F)
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
Ambient Relative Humidity 5% to 95% Non-condensing
Ambient Storage Temperature -40 to 85 °C
(-40 to 185 °F)