EasyManua.ls Logo

Siemens RUGGEDCOM RX5000 - Other Approvals; EMC and Environmental Type Tests

Siemens RUGGEDCOM RX5000
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6
Certification
RUGGEDCOM RX5000
Installation Guide
34 Other Approvals
China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic Information Products
A copy of the Material Declaration is available online at https://support.industry.siemens.com/cs/ww/en/
view/109738831.
Section6.1.9
Other Approvals
This device meets the requirements of the following additional standards:
IEEE 1613
IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric
Power Substations
IEC 61850-3
Communications Networks and Systems for Power Utility Automation – Part 3: General Requirements
IEC 61000-6-2
Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments
Section6.2
EMC and Environmental Type Tests
The RUGGEDCOM RX5000 has passed the following EMC and environmental tests.
IEC 61850-3 EMC Type Tests
Test Description Test Levels
Severity
Levels
Enclosure Contact +/- 8 kV 4
IEC 61000-4-2 ESD
Enclosure Air +/- 15 kV 4
IEC 61000-4-3 Radiated RFI Enclosure Ports 20 V/m Note
a
Signal ports +/- 4 kV @ 2.5 kHz Note
a
DC Power ports +/- 4 kV 4
AC Power ports +/- 4 kV 4
IEC 61000-4-4 Burst (Fast Transient)
Earth ground ports +/- 4 kV 4
Signal ports
+/- 4 kV line-to-earth,
+/- 2 kV line-to-line
4
DC Power ports
+/- 2 kV line-to-earth,
+/- 1 kV line-to-line
3
IEC 61000-4-5 Surge
AC Power ports
+/- 4 kV line-to-earth,
+/- 2 kV line-to-line
4
Signal ports 10 V 3
IEC 61000-4-6 Induced (Conducted) RFI
D.C Power ports 10V 3