EasyManua.ls Logo

Siemens SCALANCE M874-3 - Accessories

Siemens SCALANCE M874-3
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connecting SCALANCE M-800 to WAN
1.1 Connecting M874 with the mobile wireless network
SCALANCE M-800 Getting Started
Getting Started, 06/2015, C79000-G8976-C337-04
17
6. Repeat the password in "Password Confirmation" to confirm it. The entries must match.
7. Click the "Set Values" button.
Result
The password for the "admin" user is changed. The changes take immediate effect.
1.1.5
Changing the IP settings of the M874
The following IP address settings are made for the devices in this configuration example:
IP address
Subnet mask
SCALANCE M-800
192.168.100.1
255.255.255.0
Admin PC
192.168.100.20
255.255.255.0
Procedure
1. Click "System" > "Agent IP" in the navigation area.
2. Enter 192.168.100.1 in "IP Address" and 255.255.255.0 in "Subnet Mask".
3. Click "Set Values".
The IP address is adjusted automatically in the address bar of the Web browser. The
Web browser on the Admin PC can no longer access Web Based Management because
its IP settings no longer match.
4. On the Admin PC, open the Control Panel with the menu command "Start" > "Control
Panel".
5. Click "Network and Sharing Center" and select the "Change Adapter Settings" option in
the navigation menu on the left.