VPN tunnel between SCALANCE M87x and SINEMA RC Server
5.3 Configure a remote connection on the SINEMA RC Server
SCALANCE M-800 Getting Started
188 Getting Started, 06/2015, C79000-G8976-C337-04
5.3
Configure a remote connection on the SINEMA RC Server
5.3.1
Creating node groups
Users and devices can be put together in participant groups. You can also specify whether
the communication between the participants of an individual group is permitted or forbidden.
For this sample configuration, the following groups are created.
Station -1
Station-2
Service
Requirement
The SINEMA RC Server is connected to the WAN.
Procedure
1. In the address box of the Web browser, enter the WAN IP address of the SINEMA RC
Server "https://<WAN IP address>", see table "Settings used (Page 181)".
2. Log in as the "admin" user and with the corresponding password.
3. In the navigation area, click "Remote connections" > "Participant groups". The participant
groups that have already been created are listed in the content area.
4. Click "Create". The page "New participant group" is opened.
5. Enter "Station 1" for group name and click "Exit".
6. Repeat steps 1 - 3 for the groups "Station-2" and "Service"